Guide to reading Serial Port data from a load cell in C#

In electronic weighing systems, the load cell is typically connected to an indicator, which then outputs data via a Serial port (RS232 / RS485). The task of C# is to read and process this data.


1. Working Principle

Basic flow:

Load cell → Indicator → Serial (COM) → C# reads data

The indicator sends data as a string, for example:

ST,GS,+00012.34kg

or

+12.34

2. Preparation

Hardware

  • Load cell + indicator
  • RS232 or RS485 cable (USB converter may be required)

Serial Parameters (very important)

You must check the correct parameters from the device:

  • BaudRate: 9600 / 19200 / 38400
  • DataBits: 7 or 8
  • Parity: None / Even / Odd
  • StopBits: 1 or 2

Common example:

9600, 8, N, 1

3. C# Code to Read Serial Port

Use the library:

using System.IO.Ports;

Basic Example

SerialPort serialPort = new SerialPort(“COM3”, 9600, Parity.None, 8, StopBits.One);

private void Form1_Load(object sender, EventArgs e)
{
serialPort.DataReceived += SerialPort_DataReceived;
serialPort.Open();
}

private void SerialPort_DataReceived(object sender, SerialDataReceivedEventArgs e)
{
string data = serialPort.ReadLine();
Invoke(new Action(() =>
{
txtWeight.Text = data;
}));
}


4. Processing Load Cell Data

Actual data often contains extra characters and needs filtering.

Example received string:

ST,GS,+00012.34kg

Extract numeric value:

string raw = “ST,GS,+00012.34kg”;
string weight = System.Text.RegularExpressions.Regex
.Match(raw, @”[-+]?\d*\.?\d+”)
.Value;

txtWeight.Text = weight;


5. Data Reading Modes

5.1 ReadLine (most common)

Used when data ends with newline (\n):

serialPort.ReadLine();

5.2 ReadExisting

string data = serialPort.ReadExisting();

5.3 Read bytes (advanced)

byte[] buffer = new byte[serialPort.BytesToRead];
serialPort.Read(buffer, 0, buffer.Length);

6. Common Issues and Solutions

6.1 No data received

  • Wrong COM port
  • Wrong BaudRate
  • Port not opened

6.2 Garbled data

  • Wrong Parity / DataBits
  • RS232 vs RS485 mismatch

6.3 DataReceived event not triggered

  • Event not assigned
  • Device not sending data

6.4 Application freezes

  • Not using Invoke() when updating UI

7. Quick Testing with Software

Before coding, test using:

  • Hercules
  • Serial Port Monitor
  • PuTTY

→ If these tools cannot read data → C# won’t either


8. Practical Tips

Always ask the manufacturer:

  • Data format
  • Protocol (ASCII or Modbus)

If using RS485:

  • It may use Modbus RTU → not simple string reading

Some indicators require sending a command before returning data.


9. Advanced Example (Auto Reconnect)

private void ConnectSerial()
{
try
{
if (!serialPort.IsOpen)
{
serialPort.Open();
}
}
catch
{
// retry later
}
}

Conclusion

Reading load cell data via Serial in C# is not difficult. The most important points are:

  • Correct COM parameters
  • Understanding the data format
  • Proper string processing

Để lại một bình luận